A/R
A/R describes a geometric characteristic of all compressor and turbine housings. It is defined as the inlet cross-sectional area divided by the radius from the turbo centerline to the centroid of that area.

Compressor A/R - Compressor performance is largely insensitive to changes in A/R, but generally larger A/R housings are used to optimize the performance for low boost applications, and smaller housings are used for high boost applications. Usually there are not A/R options available for compressor housings.

Turbine A/R - Turbine performance is greatly affected by changing the A/R of the housing. Turbine A/R is used to adjust the flow capacity of the turbine. Using a smaller A/R will increase the exhaust gas velocity into the turbine wheel, causing the wheel to spin faster at lower engine RPMs giving a quicker boost rise. This will also tend to increase exhaust backpressure and reduce the max power at high RPM. Conversely, using a larger A/R will lower exhaust gas velocity, and delay boost rise, but the lower backpressure will give better high RPM power. When deciding between A/R options, be realistic with the intended vehicle use and use the A/R to bias the performance toward the desired powerband.
 
Choke Line
The choke line is on the right hand side of a compressor map and represents the flow limit. Properly sizing a turbo is important to prevent the compressor from operating past the choke line. When a turbocharger is run deep into choke, turbo speeds increase dramatically while compressor efficiency plunges (very high compressor outlet temps). Additionally, the turbo's durability is compromised by the resulting high thrust loads.
 
CHRA
(Center Housing & Rotating Assembly)
The CHRA is essentially a turbocharger minus the compressor and turbine housings
 
Clipped Turbine Wheel
When an angle is machined on the turbine wheel exducer (outlet side), the wheel is said to be "clipped". Clipping causes a minor increase in the wheel's flow capability; however, it dramatically lowers the turbo efficiency. This reduction in efficiency causes the turbo to come up on boost at a later engine speed (ex. increased turbo lag). High performance applications should never use a clipped turbine wheel.
 
Corrected Air Flow
When plotting actual airflow data on a compressor map, the flow must be corrected to account for different atmospheric conditions that affect air density.
 
Example:
Air Temperature (Air Temp) - 60°F
Barometric Pressure (Baro) - 14.7 psi
Engine air consumption (Actual Flow) = 50 lb/min
Corrected Flow= Actual Flow SQR([Air Temp+460]/545)/ Baro/13.95
Corrected Flow= 50*SQR([60+460]/545)/ 14.7/13.95 = 46.3 lb/min
 
Efficiency Contours
The efficiency contours depict the regional efficiency of the compressor stage. When sizing a turbo, it is important to maintain the proposed lugline with a high efficiency range on the map.
 
Free-Float
A free-floating turbocharger has no Wastegates device. This turbocharger can't control its own boost levels. For performance applications, the user normally must install an external Wastegates.
 
On-Center Turbine Housings
On-center turbine housings refer to an outdated style of turbine housing with a centered turbine inlet pad. The inlet pad is centered on the turbo's axis of rotation instead of being tangentially located. Using an on-center housing will significantly lower the turbine's efficiency. This results in increased turbo lag, more backpressure, lower engine volumetric efficiency, and less overall engine power.
 
Pressure Ratio
Ratio of absolute outlet pressure divided by absolute inlet pressure
Example:
Intake manifold pressure (Boost) = 12 psi
Pressure drop, intercooler (DPIntercooler) = 2 psi
Pressure drop, air filter (DPAir Filter) = 0.5 psi
Atmosphere (Atmos) = 14.7 psi at sea level
PR = (Boost + DPIntercooler+ Atmos) / (Atmos-DPAir Filter)
PR = (12 + 2 + 14.7) / (14.7 -.5) = 2.02
 
Surge Line
The surge region, located on the left-hand side of the compressor map, is an area of flow instability typically caused by compressor inducer stall. The turbo should be sized so that the engine does not operate in the surge range. When turbochargers operate in surge for long periods of time, bearing failures may occur.
 
Trim
Trim is an area ratio used to describe both turbine and compressor wheels. Trim is calculated using the inducer and exducer diameters.
Example:
Inducer diameter = 88mm
Exducer diameter = 117.5mm
Trim = Inducer2/Exducer2
Trim = 882/117.52 = 56 Trim

As trim is increased, the wheel can support more air/gas flow.

Wastegates
A Wastegated turbocharger includes an integral device to limit turbo boost. This consists of a pneumatic actuator connected to a valve assembly mounted inside the turbine housing. By connecting the pneumatic actuator to boost pressure, the turbo is able to limit its maximum boost output. The net result is increased durability, quicker time to boost, and adjustability of boost.